Battery Impedance Tester, health of lead-acid cells up to 2000 Ah, Pass/Warning/Fail calculations, impedance, interconnection resistance and cell voltage, Windows CE operating system with 32 MB of memory, Measures float and ripple currents, Includes PowerDB LITE Management Software.
Rental Prices
Price excl.VAT
24 €/day*
Sale prices
Price excl.VAT
Warranty
New
5880 €
24 month(s)
Contact us
Contact us
Options pour BITE 3
CAL
Standard Calibration
274 €
* Price per day for a period of 3 months, minimum of one week rental.
POWER HiTESTER, Ultra high-sensitive measurement, for use to measure an effective power of equipment in stand-by mode: Current 1.0000 mA full-scale, 0.1 µA resolution. Wide measurement range, up to 50.000 A direct input. Voltage, Current, Current peak, Active power, Apparent power, Reactive power, Power factor, Phase angle, Frequency, Power integration, Current integration.
Power Quality Clamp Meter. AC/DC current : Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit. View graphs and generate reports : With included Power Log software.
Power Quality Analyser, Waveform Bargraph showing harmonic levels Numeric values. 5.0 V to 600 V rms (AC+DC); ±5.0 V to ±933 V, 1.00 A to 1000 A rms (AC+DC); ±1.0 A to ±2000, 0.0W(VA) to 600 kW(kVA) average. Isolated RS-232 Cable - FlukeView® Software - Software Manual - 80i-500s AC Current Probe.
Three-phase power quality analyzer, Highest safety rating in the industry – 600V Cat IV / 1000V CAT III, Automatic transient mode captures 200kHz waveform data on all phases simultaneously, Measure all three phases and neutral with included 4 current probes (i400s), AutoTrend: every measurement you see is always automatically recorded, System-Monitor : Up to seven power quality parameters on one screen according to EN50160.
Main Power Analyser, Harmonic Measurement up to 51th row, Transition up to 40ns, 2 Channels Oscilloscopes, 10 Screen Data Storage or by Software, delivered with its case, with Current Probe and all accessories
8 kW Power Meter, 100mV…500 V, current range 1mA…16 A, Frequency range DC…1 kHz, Display of apparent, effective and reactive power, Galvanically isolated USB/RS-232 Interface, optional IEEE-488.
Battery Impedance Tester, health of lead-acid cells up to 2000 Ah, Pass/Warning/Fail calculations, impedance, interconnection resistance and cell voltage, Windows CE operating system with 32 MB of memory, Measures float and ripple currents, Includes PowerDB LITE Management Software.
Battery HiTester, Resistance Measurement 3 m-Ohm to 3 Ω, 4 ranges, 1 µΩ resolution max, Voltage Measurement 6 or 60 V DC, 2 ranges, 1 mV resolution max, Temperature Measurement 10 to 60 C, 1 range, 0.1 C resolution (platinum sensor), Sampling rate Once per second, Comparator functions Setting First and second resistance limits, and lower voltage limit, Output : LCD, beep, Other functions Data memory, PC interface (USB), Power supply AA (LR6) Alkaline Batteries 8.
Multifunctions installation controller. (IEC 60364-6, NF C 15-100, VDE 100, FD C 16-600, etc).
Measurements: Insulation, earth measurement (1P, 1P selective, 3P, earth under voltage (earth loop), DDR test, continuity, voltage, current, frequency, phase rotation.
Measure of active power: by current probes (in option).
3 phases main power analyser, EN 50160, TRMS 830V and 3000A, frequency 40 to 70 Hz, harmonic up to 50th row, transients, memory 4 Mo, application software, delivered with its carrying bag, current probes (AmpFLEX included) and all accessories.
The Qualistar measures all the voltage, current and power parameters required for full diagnosis of an electrical installation. It simultaneously captures and records all the parameters, transients, alarms and wave forms. 4 voltage inputs, up to 1,200 V, 4 current inputs, up to 6,500 A (depending on sensors), Electrical safety: IEC 61010 600 V CAT IV / 1,000 V CAT III, Simultaneous real-time display of all 4 inputs is available in graphic, vectorial or value-table format. In Inrush mode, the measurement covers a duration of more than 1 minute ! The Qualistar+ can also capture and record : the Min/Max values - up to 300 transients, harmonics up to the 50th order, 50 screens and curves, 10,000 alarms of 40 different types. Colour-coded rings for easy identification of connections - compact and lightweight : only 1.9 kg.
The Qualistar measures all the voltage, current and power parameters required for full diagnosis of an electrical installation. It simultaneously captures and records all the parameters, transients, alarms and wave forms. 4 voltage inputs, up to 1,200 V, 4 current inputs, up to 6,500 A (depending on sensors), Electrical safety: IEC 61010 600 V CAT IV / 1,000 V CAT III, Simultaneous real-time display of all 4 inputs is available in graphic, vectorial or value-table format. In Inrush mode, the measurement covers a duration of more than 1 minute ! The Qualistar+ can also capture and record : the Min/Max values - up to 300 transients, harmonics up to the 50th order, 50 screens and curves, 10,000 alarms of 40 different types. Colour-coded rings for easy identification of connections - compact and lightweight : only 1.9 kg.